Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Pesqui. bras. odontopediatria clín. integr ; 24: e220200, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1550592

ABSTRACT

ABSTRACT Objective: To evaluate the prevalence of sharps accidents among dental students in southwest Goiás state, Brazil, and further survey their knowledge of biosafety and post-injury management. Material and Methods: A cross-sectional analytical observational study was carried out in 2018 following the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) guidelines. The study population included dental students in the 4th and 10th course semester. A pre-formulated self-administered questionnaire containing 14 objective questions was used for data collection. Mean and standard deviation values were calculated. Results: A total of 308 responses were obtained. Overall, 15.9% of the respondents reported having previously experienced accidents with sharps. Most dental students who claimed to know the biological risks to which they are exposed were in the 5th and 8th course semesters, and 67.2% of them reported knowing how to proceed in the event of a sharp accident. Conclusion: A low prevalence of sharps accidents has been reported, and dental students are considered to have a good knowledge of biosafety.

2.
RGO (Porto Alegre) ; 71: e20230055, 2023. graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1521438

ABSTRACT

ABSTRACT Objective: The present study analyzed the biomechanical behavior of the generated stress on the external surface of the rehabilitation elements (implants, components and infrastructures) according to different occlusion patterns on a fixed partial denture on osseointegrated implants. Method: The experimental groups varied according to the location of the occlusal load applied to the Fixed partial denture, with a total occlusal load of 750N in all groups, opting for greater loads on the occlusal table of the molar in relation to the premolar. This evaluation was performed by the finite element method with simulations by the AnsysWorkbench 16.0 Software program. Results: The results analyzed for implants and their components showed that the more posterior the occlusal loading, the greater the stress developed (group 4), always in the connection area between the prosthetic component and the implant, as this location can induce greater screw loosening. The results analyzed for the infrastructures showed that the most distributed occlusal loading possible (group 1) is the best situation for generating less stress. However, even in group 3 which obtained the highest stresses in the critical area of the prosthetic connection, the zirconia flexural strength values generated were not worrisome. Conclusion: It can be concluded that the occlusal adjustment of Fixed partial dentures are preponderant and decisive factors for correct biomechanics and preservation of the system in the long term in order to avoid possible damage and/or failures, and exert significant and notorious differences in the behavior of all structures studied herein.


RESUMO Objetivo: O presente estudo analisou o comportamento biomecânico do estresse gerado na superfície externa dos elementos reabilitadores (implantes, componentes e infraestruturas) de acordo com diferentes padrões de oclusão em uma prótese parcial fixa sobre implantes osseointegrados. Métodos: Os grupos experimentais variaram de acordo com a localização da carga oclusal aplicada na Prótese Parcial Fixa, com carga oclusal total de 750N em todos os grupos, optando por cargas maiores na mesa oclusal do molar em relação ao pré-molar. Esta avaliação foi realizada pelo método dos elementos finitos com simulações pelo programa AnsysWorkbench 16.0 Software. Resultados: Os resultados analisados para os implantes e seus componentes mostraram que quanto mais posterior a carga oclusal, maior a tensão desenvolvida (grupo 4), sempre na área de conexão entre o componente protético e o implante, pois este local pode induzir maior soltura do parafuso. Os resultados analisados para as infraestruturas mostraram que a carga oclusal mais distribuída possível (grupo 1) é a melhor situação para gerar menos estresse. No entanto, mesmo no grupo 3 que obteve as maiores tensões na área crítica da conexão protética, os valores de resistência à flexão da zircônia gerados não foram preocupantes. Conclusões: Pode-se concluir que o ajuste oclusal das Próteses Parciais Fixas são fatores preponderantes e decisivos para correta biomecânica e preservação do sistema a longo prazo a fim de evitar possíveis danos e/ou falhas, e exercem diferenças significativas e notórias no comportamento de todas as estruturas aqui estudadas.

3.
RFO UPF ; 21(3): 369-373, 15/12/2016.
Article in Portuguese | LILACS | ID: biblio-848637

ABSTRACT

A celulite facial é a difusão de processo inflamatório por planos subcutâneos em tecidos moles, podendo ter sua etiologia oriunda de variados fatores, sendo, dentre eles, a origem odontogênica a mais comumente encontrada. Entretanto, a celulite facial pode também estar relacionada a causas menos comuns, como processos infecciosos de origem não odontogê- nica. Objetivo: o presente relato de caso vem a elucidar o início de um processo infeccioso gerado por acne inflamada na borda inferior do lábio, a qual foi a porta de entrada para bactérias, o que gerou a difusão do processo inflamatório para planos subcutâneos e originou uma celulite facial. Relato de caso: pelo fato de não haver agente causal específico, como as originadas por causa odontogênica, foi estabelecido tratamento com antibióticoterapia de amplo espectro, associado à meticulosa higienização e terapia com calor, a fim de induzir abscedação espontânea. Exames específicos laboratoriais também foram solicitados para maior segurança e diagnóstico preciso do profissional. A evolução do caso transcorreu em oito dias, de forma rápida e aguda, principalmente nos primeiros cinco dias. Considerações finais: conforme relatado no caso, a interação entre o cirurgião-dentista e o médico bem como a presença da interdisciplinaridade foram fatores fundamentais no tratamento como um todo e para a resolução do caso de forma satisfatória, uma vez que a ocorrência de celulite facial nessa área não é geralmente presenciada.

4.
Braz. dent. sci ; 19(3): 106-110, 2016. ilus
Article in English | LILACS, BBO | ID: biblio-830979

ABSTRACT

Subcutaneous emphysema is an event often generated by iatrogenic reason, caused by improper dissection of air into soft tissues and/ or anatomical structures, causing edema and visually noticeable volumetric change in the area of the incident. The main etiological factor for this is the use of equipment such as air syringe or high-speed handpieces in surgical procedures of greater magnitude; however, subcutaneous emphysema may also occur in simple procedures, such that presented in this case report, through using air-abrasive device usually proper for dental prophylaxis. This case report aimed to describe the care measurements to avoid such event, describing proper procedures for the correct solution of the case, as well as to alert the professionals about the risks and necessary precautions.


O enfisema subcutâneo é um evento muitas vezes de origem iatrogênica, causado pela infusão indevida de ar nos tecidos e/ou estruturas anatômicas, causando edemaciamento e alteração volumétrica visualmente perceptível na área do ocorrido. O principal fator etiológico para tal é o uso de equipamentos como seringa tríplice ou caneta de alta rotação durante procedimentos cirúrgicos de maior magnitude; no entanto, o enfisema subcutâneo também pode ocorrer diante de procedimentos mais simples, tal como o ocorrido no presente relato de caso, em que houve sua ocorrência pelo uso de equipamento de ar comprimido usualmente utilizado para execução de profilaxia. O objetivo do presente artigo foi relatar o caso, assim como descrever os cuidados para se evitar tal evento, e descrever procedimentos adequados para o correto prosseguimento e resolução adequada do caso.


Subject(s)
Humans , Compressed Air , Subcutaneous Emphysema
5.
Full dent. sci ; 6(21): 73-80, dez. 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-750185

ABSTRACT

A Implantodontia caracterizou-se como um dos grandes avan‡os dentro da Odontologia moderna. Nas £ltimas d‚cadas, as inova‡ães e desenvolvimento dos implantes dent rios tˆm sido crescentes, e na necessidade de acompanhar tais evolu‡ães, as t‚cnicas no campo das pr¢teses e reabilita‡ães tamb‚m tiveram de se reinventar. Atualmente, um dos grandes trunfos do uso dos implantes dent rios ‚ associ -los a uma restaura‡Æo imediatamente ap¢s sua implanta‡Æo, com ganhos funcionais e, especialmente, est‚ticos. A previsibilidade do tratamento ‚ indispens vel no sucesso do mesmo. Assim, ‚ poss¡vel prever o posicionamento mais ideal para a restaura‡Æo imediata. Al‚m disso, configura-se como indispens vel a rapidez do procedimento, uma vez que quanto menos exposto ficar o campo cir£rgico, melhor ser  o comportamento p¢s-operat¢rio da regiÆo reabilitada. Portanto, no intuito de se conciliar fidelidade de posicionamento da restaura‡Æo imediata com rapidez e otimiza‡Æo do tempo transoperat¢rio, este artigo e seus autores se propãem a compartilhar uma t‚cnica desenvolvida para viabiliza‡Æo de tal procedimento de forma r pida e previs¡vel (T‚cnica da muralha e faceta adaptada - Palhares e Toniollo).


Implantology is one of the great advances in modern Dentistry. In recent decades innovations and development of dental implants are occurring continuously thereby techniques and rehabilitation also had to be reinvented. Currently, one of the great advantages of the use of dental implants is the possibility of associating them to a restoration immediately after their deployment, with functional and especially aesthetic gains. Predictability is essential to the success of the treatment. Thus, it is possible to predict the most optimal placement for the immediate restoration. Accelerating the procedure also seems to be fundamental since the less exposed the surgical field, the better the postoperative behavior of the rehabilitated area. Therefore, in order to reconcile fidelity and fast positioning of the immediate restoration to optimize time, this article and its authors intended to share a technique developed for the feasibility of this procedure in a quick and way (Technique of the wall and adapted veneer - Palhares and Toniollo).


Subject(s)
Humans , Male , Adult , Esthetics, Dental , Dental Implantation , Denture Design , Dental Restoration, Temporary , Silicones , Tomography, X-Ray Computed/instrumentation
6.
Full dent. sci ; 5(18): 311-319, abr. 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-716612

ABSTRACT

pós o advento e sucesso comprovado da ósseointegração, a Implantodontia teve sua ascensão de forma rápida, previsível, consolidada e resolutiva. Para o efetivo e correto funcionamento do tratamento reabilitador utilizando os implantes dentários é necessário que se respeite os diversos fatores que permeiam seu comportamento biomecânico, mas também que se preze pelos fatores diretamente atrelados ao sucesso esperado pelo paciente que, muitas vezes, é relacionado à chamada “estética vermelha”, a qual tem extrema responsabilidade no resultado final do tratamento. Para isso, não só a fim de obter contorno, suporte e harmonia do tecido mole marginal à prótese sobre implante, mas também visando a manutenção e respeito a essa estrutura tão nobre, faz-se conveniente a moldagem personalizada do perfil de emergência da referida região, principalmente em casos unitários, a fim de preservar toda a estrutura conseguida por meio do uso dos provisórios. Este artigo traz um relato de caso clínico em que tal procedimento de extrema valia é descrito detalhadamente no intuito de ser reproduzível por outros profissionais da área na intenção de se obter máximo resultado estético, respeitando-se as estruturas nobres circunjacentes ao implante e respectiva reabilitação.


After the advent and proven success of osseointegration, Implantology raised quickly, predictably, in a consolidated and resolute way. For effective and proper effect of rehabilitation treatment with dental implants it is necessary to respect the various factors involved in its biomechanical behavior, but also by respect the expectation of the patient regarding the success of the treatment. This is often related to the call “red aesthetic” that has an important role on the treatment outcome. Therefore besides obtaining contour, support, and harmony of the peri-implant soft tissue, in order to maintain and respect this noble structure, it is recommended to make a customized molding of the emergency profile of that region, especially in single cases, preserving the whole structure obtained through the use of provisional prosthesis. This article presents a case report in which this procedure is described in details so that other professionals may reproduce it in an attempt to obtain maximum aesthetic result respecting the noble structures surrounding the implant and their rehabilitation


Subject(s)
Adult , Dental Impression Materials , Esthetics, Dental , /methods , Peri-Implantitis/diagnosis , Peri-Implantitis , Dental Prosthesis, Implant-Supported/methods
7.
Braz. j. oral sci ; 11(4): 440-444, Oct.-Dec. 2012. ilus, tab
Article in English | LILACS, BBO | ID: lil-668669

ABSTRACT

Aim: To explore the biomechanical effects of the different implantation bone levels of Morse taper implants, employing a finite element analysis (FEA). Methods: Dental implants (TitamaxCM) with 4x13 mm and 4x11 mm, and their respective abutments with 3.5 mm height, simulating a screwed premolar metal-ceramic crown, had their design performed using the software AnsysWorkbench10.0. They were positioned in bone blocks, covered by 2.5 mm thickness of mucosa. The cortical bone was designed with 1.5 mm thickness and the trabecular bone completed the bone block. Four groups were formed: group 11CBL (11 mm implant length on cortical bonelevel), group 11TBL (11 mm implant length on trabecular bone level), group 13CBL (13mm implant length on cortical bone level) and group 13TBL (13 mm implant length on trabecular bonelevel). Oblique 200 N loads were applied. Von Mises equivalent stresses in cortical and trabecular bones were evaluated with the same design program. Results: The results were shown qualitatively and quantitatively by standard scales for each type of bone. By the results obtained, it can be suggested that positioning the implant completely in trabecular bone brings harm with respect to the generated stresses. Its implantation in the cortical bone has advantages with respect to better anchoring and locking, reflecting a better dissipation of the stresses along the implant/bone interfaces. In addition, the search for anchoring the implant in its apical region in cortical bone is of great value to improve stabilization and consequently better stress distribution.Conclusions: The implant position slightly below the bone in relation to the bone crest brings advantages as the best long-term predictability with respect to the expected neck bone loss.


Subject(s)
Biomechanical Phenomena , Dental Implants , Bone and Bones/anatomy & histology
8.
Braz. dent. j ; 23(5): 496-501, Sept.-Oct. 2012. ilus, graf, mapas, tab
Article in English | LILACS | ID: lil-660350

ABSTRACT

The effects of fluoride, which is present in different oral hygiene products, deserve more investigation because little is known about their impact on the surface of titanium, which is largely used in Implantology. This study evaluated the surface of commercially pure titanium (cpTi) after exposure to different concentrations of sodium fluoride (NaF). The hypothesis tested in this study was that different concentrations of NaF applied at different time intervals can affect the titanium surface in different ways. The treatments resulted in the following groups: GA (control): immersion in distilled water; GB: immersion in 0.05% NaF for 3 min daily; GC: immersion in 0.2% NaF for 3 min daily; GD: immersion in 0.05% NaF for 3 min every 2 weeks; and GE: immersion in 0.2% NaF for 3 min every 2 weeks. The experiment lasted 60 days. Roughness was measured initially and every 15 days subsequently up to 60 days. After 60 days, corrosion analysis and anodic polarization were done. The samples were examined by scanning electron microscopy (SEM). The roughness data were analyzed by ANOVA and there was no significant difference among groups and among time intervals. The corrosion data (i corr) were analyzed by the Mann-Whitney test, and significant differences were found between GA and GC, GB and GC, GC and GD, GC and GE. SEM micrographs showed that the titanium surface exposed to NaF presented corrosion that varied with the different concentrations. This study suggests that the use of 0.05% NaF solution on cpTi is safe, whereas the 0.2% NaF solution should be carefully evaluated with regard to its daily use.


Os efeitos do fluoreto, o qual está presente em diferentes produtos de higiene oral, necessita de maiores investigações, pois pouco se sabe sobre seus efeitos na superfície do titânio, o qual possui amplo uso na implantodontia. Este estudo objetivou avaliar a superfície do titânio comercialmente puro (cpTi) após exposição a diferentes concentrações de fluoreto de sódio (NaF). A hipótese testada neste estudo foi que diferentes concentrações de NaF aplicadas em diferentes intervalos de tempo seriam capazes de afetar diferentemente a superfície do titânio. Os tratamentos realizados foram: GA (controle): imersão em água destilada; GB: imersão diária por 3 min em NaF a 0,05%; GC: imersão diária por 3 min em NaF a 0,2%; GD: imersão quinzenal por 3 min em NaF a 0,05%; e GE: imersão quinzenal por 3 min em NaF a 0,2%. O tempo do experimento foi de 60 dias. A análise da rugosidade foi efetuada inicialmente e a cada 15 dias. Após 60 dias foi realizada análise de corrosão e polarização anódica. As amostras foram analisadas em MEV. Os dados de rugosidade foram analisados por ANOVA e não houve diferença estatisticamente significante entre grupos e entre tempos. Os dados de corrosão (i corr) foram analisados pelo teste de Mann-Whitney e foram encontradas diferenças significantes entre GA e GC, GC e GB, GC e GD, GC e GE. A MEV evidenciou que a superfície do titânio exposto ao NaF apresentou corrosão variando de acordo com a concentração. Com base nos dados encontrados conclui-se que o uso de solução NaF a 0,05% em cpTi é seguro, enquanto a solução NaF 0,2% para uso diário deve ser cuidadosamente avaliada.


Subject(s)
Corrosion , Mouthwashes/chemistry , Sodium Fluoride/chemistry , Titanium/chemistry , Analysis of Variance , Electrochemical Techniques , Microscopy, Electron, Scanning , Surface Properties
9.
Full dent. sci ; 3(11): 286-291, abr.-jun. 2012. ilus
Article in Portuguese | LILACS, BBO | ID: lil-681658

ABSTRACT

A Implantodontia vem se destacando entre as diversas áreas da Odontologia moderna. As possibilidades de tratamento envolvendo os implantes dentários têm facilitado e ampliado a gama de opções ao cirurgião dentista. No entanto, a proposta de tratamento envolvendo reabilitação sobre implantes traz consigo problemas a serem solucionados, já que tal tratamento também é passível de intercorrências. A curva de aprendizagem com o emprego da Implantodontia deve ser respeitada, já que tanto na fase cirúrgica quanto na fase protética, existem critérios a serem respeitados para um bom prognóstico do tratamento. Além disso, quando surgem as intercorrências é imprescindível o preparo e conhecimento do profissional em questão. O presente caso clínico relata uma reabilitação unitária sobre implante, a qual necessitou ser realizada fora dos padrões normais da Implantodontia, já que foi constatada deformação na plataforma hexagonal do mesmo. É possível que tal ocorrência tenha sido causada na fase cirúrgica, durante a instalação do implante, devido a um provável torque excessivo, resultando na impossibilidade da adaptação dos componentes protéticos. A resolução do caso ocorreu com a instalação de um núcleo metálico fundido sobre o implante e confecção de prótese metalocerâmica cimentada. Com o presente relato, pode-se notar a importância do conhecimento de conceitos básicos por parte do cirurgião dentista, assim como sua flexibilidade frente às intercorrências do tratamento


The Implantology has become highlighted among the various areas of modern dentistry. The treatment possibilities involving dental implants have facilitated and expanded the range of options to the dentist. However, the treatment involving rehabilitation with implants can bring problems to be solved, as this treatment is also susceptible to complications. Learning curve with the use of implants should be respected, both in the surgical and prosthetic phases, because there are criteria to be met for a good treatment prognosis. Also, when complications occur, it is essential preparation and knowledge of the professional. This case report describes unit rehabilitation with implant, which needed to be performed outside of the normal standards of implant dentistry, as was observed deformation on the hexagonal platform. It is possible that it has been caused during implant installation surgery phase, due to an excessive torque, resulting in the inability to adapt the prosthetic components. The case resolution was with the installation of a cast metal core on the implant and making a metaloceramic cemented prosthesis. With this case report may be noted the importance of knowledge of basic concepts by the dentist, as well as its flexibility in the face of complications of treatment


Subject(s)
Humans , Dental Implants , Dental Prosthesis, Implant-Supported/methods , Dental Prosthesis, Implant-Supported , Denture, Partial, Fixed , Mouth Rehabilitation/methods , Mouth Rehabilitation
10.
Rev. Assoc. Paul. Cir. Dent ; 65(3): 221-226, maio-jun.2011.
Article in Portuguese | LILACS, BBO | ID: lil-599332

ABSTRACT

A Odontologia Estética trouxe para a realidade do consultório odontológico atual a mimetização das nuances de cor, texturas e características ópticas para reabilitações realizadas em porcelana. Para que este fato ocorra, é necessário que uma boa parte das características estruturais de um dente natural seja reproduzida. O esmalte dental é reproduzido com sucesso satisfatório através da utilização de técnicas inovadoras e porcelanas de qualidade avançada. A dentina também deve ser reproduzida, e para que isso seja possível em reabilitações sobre implantes surgiu a possibilidade de serem confeccionados pilares em porcelana pura do tipo zircônia. São pilares instituídos com a proposta de oferecer resistência mecânica satisfatória à sustentação de coroas sobre implantes, além da condição estética. Desta forma, descreveu-se o caso clínico que visou a utilização de um implante imediato ativado imediatamente com a utilização de um provisório sobre o implante posicionado na região do dente 22 de uma paciente de 33 anos. Como o objetivo principal do caso foi atingir excelência em estética, optou-se pela utilização de um pilar de zircônia (CONEXÃO@) sobre o implante colocado. Verificou-se, além de benefícios estéticos, saúde gengival na área implantada, pois a zircônia possui biocompatibilidade e filia aos tecidos vivos quando comparada a pilares sobre implantes confeccionados em metal. O caso clínico vem sendo acompanhado com proservação de 7 anos. Conclui-se que a opção da utilização dos novos pilares em zircônia traz para os casos de reabilitação sobre implantes uma resolução mais interessante para os anseios estéticos e funcionais dos pacientes da atualidade.


Esthetic Dentistry has brought the reality of current dental mimicking the nuances of color,texture and optical properties for renovations carried out in porcelain. So that this does occur, it is necessary for a good part of the structural characteristics of a natural tooth to be played. The enamel is successfully reproduced satisfactorily by the use of innovative techniques and advanced quality porcelain. Dentin also be reproduced, and for this to be possible in rehabilitation on implants arose the possibility of pillars made of porcelain-type pure zirconia. Pillars are set up with the proposal to provide satisfactory mechanical strength to the support of crowns on implants in addition to the aesthetic condition. Thus, described the case history which endorsed the use of an implant immediately activated immediately by using a duty on the implant positioned in the region of tooth 22, a patient of 33 years. As the main objective of the case was achieved excellence in aesthetics, it was decided to use a pillar of zirconia (CONEXÃO SISTEMA DE PRÓTESE@) on the implant placed. It was found, and aesthetic benefits, gingival health in the area because the implanted zirconia has biocompatibility and affiliated to the living tissue quite satisfactory when compared to pillars on implants ma de of metal, and it was proved with preservation of 7 years. We conclude that the option of using new pillars in zirconia brings to the cases of rehabilitation on implants a resolution much more interesting for the aesthetic and functional desires of patients.


Subject(s)
Humans , Male , Female , Ceramics/therapeutic use , Esthetics, Dental , Dental Implants/methods , Prostheses and Implants
11.
Rev. Assoc. Paul. Cir. Dent ; 64(4): 307-314, jul.-ago. 2010.
Article in Portuguese | LILACS, BBO | ID: lil-590275

ABSTRACT

A perda dos dentes pode acarretar inúmeros problemas ao indivíduo, influenciando em suas condições gerais e sistêmicas. Acompanhada da perda dos dentes, muitas vezes ocorre a diminuição da dimensão vertical de oclusão, e, em casos extremos, o colapso oclusal. Um novo plano oclusal e o restabelecimento de uma dimensão vertical mais próxima do ideal podem ser realizados através do uso de próteses parciais removíveis corretamente indicadas e bem planejadas. Assim, com um trata- mento bastante convencional e conservador, tido por muitos profissionais como uma possibilidade obsoleta, pode-se chegar a um resultado funcionalmente e esteticamente satisfatório. No presente caso clínico, em que o paciente apresentava prótese parcial fixa provisória anterior insatisfatória e diminuição da dimensão vertical de oclusão devido a desgaste pela oclusão apenas na bateria ante- rior, com extrusão de dentes superiores e forte resistência a procedimentos cirúrgicos, foi realizada a confecção de próteses parciais removíveis superior e inferior, de forma a resgatar a dimensão vertical ideal do paciente, em sua relação cêntrica, e estabelecendo um plano oclusal mais favorável. Aliado a instalação das próteses, realizou-se restaurações nos dentes anteriores inferiores a fim de pro- porcionar overbite, overjet e guia de desoclusão corretos. Conclui-se que casos menos extensos em que é possível a restauração dos dentes anteriores de forma direta, e restabelecimento da dimensão vertical de oclusão com os dentes artificiais posteriores como suporte, utilizando-se das técnicas corretamente, as PPRs se configuram como ótima opção de tratamento.


The loss of teeth can cause many problems for the individual, acting on their general and systemíc conditions. Accompanied by loss of teeth often occurs a decrease in occlusal vertical dimension and, in extreme cases, occlusal collapse. A new occlusal plane and the restoration of a vertical dimension closest to the ideal can be achieved through the use of removable partial dentures properly displayed and well planned. So with a conventional and conservative treatment, regarded by many professionals as an obsolete possibility, vou can get a result functionally and es- thetically satisfactory.ln this case study, in which the patient had anterior unsatisfactory provisory fixed partial denture and decreased occlusal vertical dimension due to the occlusion only wear on the front battery, with extrusion of upper teeth and strong resistance to surgical procedures, upper and lower removable partial dentures were made, in order to rescue the ideal vertical dimension of the patient, in his centric relation, establishing a more favorable occlusal plane. Allied prosthesis installation, lower incisives were reconstructed with direct resin restorations in order to be pos- sible to get correct overjet, overbite and anterior guide desocclusion. It is concluded that in less extensive cases where it is possible the restoration of anterior teeth in a direct way, and restoration of vertical dimension of occlusion with posterior artificial teeth for support, using the techniques correctly, the PPRs are configured as a great option of treatment.


Subject(s)
Humans , Female , Aged , Dental Occlusion , Denture, Partial, Removable , Vertical Dimension
12.
Braz. dent. j ; 20(3): 201-204, 2009. tab
Article in English | LILACS | ID: lil-526422

ABSTRACT

This study evaluated the effects of fluoride-containing solutions on the surface of commercially pure titanium (CP Ti) obtained by casting. CP Ti specimens were fabricated and randomly assigned to 5 groups (n=10): group 1: stored in distilled water at 37 ± 1ºC; group 2: stored in distilled water at 37 ± 1ºC and daily immersed in 0.05 percent NaF for 3 min; group 3: stored in distilled water at 37 ± 1ºC and daily immersed in 0.2 percent NaF for 3 min; group 4: stored in distilled water at 37 ± 1ºC; and immersed in 0.05 percent NaF every 15 days for 3 min; and group 5: stored in distilled water at 37 ± 1ºC and immersed in 0.2 percent NaF every 15 days for 3 min. Surface roughness was measured with a profilometer immediately after metallographic polishing of the specimens (T0) and at 15-day intervals until completing 60 days of experiment (T15, T30, T45, T60). Data were analyzed statistically by ANOVA and Tukey's test (α=0.05). There was no statistically significant difference (p>0.05) in surface roughness among the solutions. In conclusion, fluoride-containing solutions (pH 7.0) used as mouthwashes do not damage the surface of cast CP Ti and can be used by patients with titanium-based restorations.


Este estudo avaliou o efeito de soluções para enxaguatório bucal contendo fluoreto sobre a superfície do titânio comercialmente puro (cp Ti) após fundição odontológica. As amostras (n=50) foram divididas igualmente: grupo A - armazenadas em água destilada a 37 ± 1ºC, grupo B - armazenadas em água destilada a 37 ± 1ºC e imersão diária em NaF a 0,05 por cento durante 3 min, grupo C - armazenadas em água destilada a 37 ± 1ºC e imersão diária em NaF a 0,2 por cento durante 3 min, grupo D - armazenadas em água destilada a 37 ± 1ºC e imersão em NaF a 0,05 por cento a cada 15 dias por 3 min e grupo E - armazenadas em água destilada a 37 ± 1ºC e imersão em NaF a 0,2 por cento a cada 15 dias durante 3 min. A rugosidade superficial foi medida logo após o polimento metalográfico das amostras (T0) e cada 15 dias de experiência até serem alcançados 60 dias (T15, T30, T45, T60). Os dados foram analisados usando ANOVA (α=0,05) e as diferenças não foram estatisticamente significantes (p>0,05) entre as diferentes soluções. Conclui-se que soluções contendo fluoreto (pH 7,0) não danificam a superfície do Ti cp e podem ser usadas como soluções para bochecho usadas por pacientes que possuem restaurações à base de titânio.


Subject(s)
Cariostatic Agents/chemistry , Sodium Fluoride/chemistry , Titanium/chemistry , Analysis of Variance , Corrosion , Dental Materials/chemistry , Statistics, Nonparametric , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL